Commercial battery storage installation: guides & comparisons
Independent guides on the decisions that matter for commercial battery storage installation: grid connection, fire safety and standards, siting and timelines. Published by SEO Dons Ltd, updated for 2026.
G98 vs G99 for a commercial battery: which route is yours?
G98 or G99 for a business battery? The 16 A per phase line, worked kW examples, why adding solar can tip a battery into G99, and what changes.
Read guide → planningBattery storage planning in Scotland: the March 2026 guidance
How planning works for battery storage in Scotland: the 50 MW route split, NPF4 policy 11, fire and water, 30 m separation, noise and decommissioning bonds.
Read guide → g99How long does a G99 application take? Clocks and delays
The DNO quotation clocks for a battery G99 application (45, 65 working days), budget estimates, the 30-90 day offer window, and what slows it down.
Read guide → g99What is a G99 application? A plain-English jargon buster
G99, Type A, DNO, IDNO, MPAN, PGMD, FON, ICP, contestable work: what each term in a battery grid-connection application actually means.
Read guide → commissioningWhat a battery commissioning handover pack should contain
The certificates, G99 records, settings and manuals a business should receive when its battery is commissioned, and why each one matters later.
Read guide → sitingHow far should a battery container be from buildings?
The 30 m starting distance in NFCC guidance, what it measures, how mitigation changes it, and how smaller battery containers are sited on business premises.
Read guide → planningWill the fire service be consulted on a battery planning application?
When English planning guidance brings the fire and rescue service into a battery application, what it will ask about, and how to prepare before you apply.
Read guide → g100G100 export limitation: batteries on a constrained grid
A constrained DNO connection does not have to rule out a battery. How a G100 export/import limitation scheme works, and when the DNO will accept one.
Read guide → fire-safetyCommercial battery fire safety: PAS 63100 vs the IET Code
PAS 63100 covers batteries in dwellings. For a commercial battery the references are BS 7671 Chapter 57, the IET Code of Practice, IEC 62933 and 62619.
Read guide → containerisedContainerised vs indoor commercial battery storage
Containerised outdoor BESS or an indoor cabinet? It comes down to capacity, space and fire strategy. An engineering comparison for UK sites.
Read guide → g99How long does a commercial battery installation take?
The physical install takes weeks, but the DNO's G99 connection sets the real programme, often months. How a commercial battery installation timeline works.
Read guide →